MicroCraft

  • TDR Tester

Automatic High Frequency Measurement System.
VNA can be installed.

E2V6151 / E3V6151 / E4V6151

E2V/E3V/E4V6151

VNA Tester
E2V6151 (2 Probe)
E3V6151 (3 Probe)
E4V6151 (4 Probe)
Installed with VNA (Vector Network Analyzer). The system automatically measures high-frequency characteristics, including S-parameters, and can be used to evaluate the characteristics of devices and boards used in 5G applications. The probes can be rotated 180° to allow close proximity to each other, direct viewing of the probing point with a CCD camera, and can connect to various VNA and TDR meters. In addition, 4-probe system are available for front and back board measurement.

Defective back drill detection by VNA measurement system

Back drill is a method of cutting out unnecessary stubs in the through-holes of a board in order to reduce transmission loss.
Typical back drill defects shown below can be detected by using VNA measurement system.

Detailed Specification

E2V6151
(2 Probe)
E3V6151
(3 Probe)
E4V6151
(4 Probe)
Max. Test Area

22.8 x 18.9” (580 x 480 mm)

22.8 x 18.9” (580 x 480 mm)

22.8 x 18.9” (580 x 480 mm)

Clamp System

Pneumatic Clamp

Pneumatic Clamp

Pneumatic Clamp

Rotate Radius

180°

180°

180°

Repeatable Accuracy X–Y

±0.16 mil (±4 µm)

±0.16 mil (±4 µm)

±0.16 mil (±4 µm)

Repeatable Accuracy θ

Air Supply: Pressure

0.5 MPa

0.5 MPa

0.5 MPa

Air Supply: Volumetric flow rate

3.5 ℓ/min.

3.5 ℓ/min.

3.5 ℓ/min.

Power Supply
Single Phase AC200–240 V 50/60 Hz

10 A

12 A

15 A

Weight

3307 lbs. (1500 kg)

3329lbs. (1510 kg)

3351lbs. (1520 kg)

Dimensions [ unit: inch(mm) ]

Required System

Control PC & Monitor *1

Operating Conditions 70–75°F (21–24°C), 30–70% relative humidity
* Do not use under the environment that has heavy condensing, dust, vibration, and/or corrosive gas.
Atmospheric Dew Point: −14°C or below (at 0.7 Mpa, dew point is 15°C or below)
Oil Mist Concentration: 1 mg/㎥ (ANR) or below

*1 Please contact our sales for details.

Supported Meter *2

Keysight Technologies

E5063A
N5224B
P5027A

Rohde & Schwarz

ZNA40
ZNB40

*2 Please contact our sales for details. Meters to be purchased separately.